N/A
|
Modes of Operation |
N/A
Automatic Intermittent Mode This mode of operation is obtained by setting the selector switch located on the control panel to "AUTO". In this mode the frequency of backwashing is controlled by a adjustable timer (1-10 min on time, 10 min to 10 hour off time) located inside the control panel. The differential pressure switch (Range 0-20 psid) is used to override the timer and commence backwashing if the differential pressure across the strainer exceeds the set value. Continuous Mode This mode is initiated by setting the selector switch to the “ON” position. During this mode of operation the strainer will continuously backwash the internal screen. |