Flash Vessel - FT Series
Fabricated Vessels
FT Series - PRODUCT DATA BULLETIN
FT Series - INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Series 'FT' Flash Tanks
COLTON flash tanks offer a unique inlet baffle arrangement designed to enhance flash separation and extend tank life.
All steam systems produce flash steam which is usually wasted when it escapes through the condensate receiver vent pipe. The COLTON flash tank allows you to use this waste energy by capturing the flash steam and using it elsewhere in your system.
Flash steam is exactly the same as live steam and is every bit as useful. Flash steam should be regarded as a free source of low pressure steam in any system that operates with more than one steam pressure.
Ordering Information Required:
- Pressure at high pressure steam trap/s or blow down metering valve/s feeding the flash tank.
- Volume of high pressure condensate (usually expressed in lbs/hr.)
- Pressure of the lower pressure system that we will be supplementing.
- Steam trap and strainer
- Pressure gage, syphon and pet cock
- Safety valve
- Drip pan elbow
- Back pressure regulator
- Pressure reducing valve
Unit of Measure
Items |
/Asset/flash-tank-image.jpg FT6-150 Flash Vessel - FT Series |
/Asset/flash-tank-image.jpg FT8-150 Flash Vessel - FT Series |
/Asset/flash-tank-image.jpg FT12-150 Flash Vessel - FT Series |
/Asset/flash-tank-image.jpg FT16-150 Flash Vessel - FT Series |
||||
A | N/A 6 in | N/A 8 in | N/A 12 in | N/A 16 in | ||||
B | N/A 47 in | N/A 48 in | N/A 49 1/2 in | N/A 58 in | ||||
C | N/A 38 in | N/A 39 in | N/A 42 in | N/A 49 in | ||||
D | N/A 13 in | N/A 14 1/2 in | N/A 20 in | N/A 23 1/2 in | ||||
E | N/A 8.00 in | N/A 8 1/2 in | N/A 12 in | N/A 13 1/2 in | ||||
F | N/A 9 in | N/A 9 1/2 in | N/A 11 1/2 in | N/A 12 1/2 in | ||||
G | N/A 25 1/2 in | N/A 26 in | N/A 27 in | N/A 32.00 in | ||||
H | N/A 2.50 in | N/A 4 in | N/A 5 in | N/A 6 in | ||||
J | N/A 3/4 in | N/A 1 in | N/A 1 1/2 in | N/A 2 in | ||||
K | N/A 8.8 in | N/A 10.8 in | N/A 14.9 in | N/A 18.9 in | ||||
L | N/A 1 1/2 in | N/A 2 in | N/A 3 in | N/A 3 in | ||||
M | N/A 2 1/2 in | N/A 3 1/2 in | N/A 5 in | N/A 5 in | ||||
Weight | N/A 75 lb | N/A 105 lb | N/A 165 lb | N/A 215 lb | ||||
Design Standards | N/A ANSI B16.5 | |||||||
Design Code | N/A ASME Section VIII, Div. 1, latest revision | |||||||
Design Pressure | N/A 285 psig | |||||||
Design Temperature | N/A 100 ºF | |||||||
M.D.M.T. | N/A -20 ºF | |||||||
Hydrostatic Test | N/A 430 psig | |||||||
Design Steam Pressure | N/A 150 psig saturated | |||||||
Heat Treatments | N/A None | |||||||
Service | N/A Non-Lethal | |||||||
Material of Construction | N/A Carbon Steel per ASME Sect. II (A) | |||||||
|