Drain Trap for Gaseous Systems - AVDT Series
Float Type Drain Traps
AVDT Series Drain Trap - PRODUCT DATA BULLETIN
AVDT Series Drain Trap - INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Series 'AVDT'
Available in sizes from 1/2" NPT to 1" npt for operating pressures up to 250 psig gaseous service at temperatures up to 250 deg. F. and specific gravities down to 0.95.
For installation at the low points of compressed air aftercoolers, separators, storage tanks, filters and compressed air mains to allow for the removal of accumulated condensate.
AVDT Models are:
Model AVDT-150: for service pressures up to 150 psig
Model AVDT-250: for service pressures up to 250 psig
Features:
- The cover is fitted with a 1/2" NPT plugged connection. This can be fitted with a full bore ball valve to allow for manual blow down during operation.
Item Number |
Orifice |
Connection Inlet Size |
Connection Outlet Size |
Body Material |
Cover Material |
Weight |
---|---|---|---|---|---|---|
AVDT-150 AVDT-150/Asset/AVDT-150-draintrap-.jpg | Orifice N/A 1.6 mm1/16 in | Connection Inlet Size N/A 3/4 in | Connection Outlet Size N/A 1/2 in | Body Material N/A Cast Iron – A126, Class B | Cover Material N/A Cast Iron – A126, Class B | Weight N/A 2.5 kg5 lb |
AVDT-250 AVDT-250/Asset/AVDT-150-draintrap-.jpg | Orifice N/A 1.6 mm1/16 in | Connection Inlet Size N/A 3/4 in | Connection Outlet Size N/A 1/2 in | Body Material N/A Cast Iron – A126, Class B | Cover Material N/A Cast Iron – A126, Class B | Weight N/A 2.7 kg6 lb |